ONLINE AND OFFLINE UPS/CVCF – Pure Agri Group https://pureagrigroup.com Thu, 14 Nov 2024 13:34:02 +0000 en-US hourly 1 https://wordpress.org/?v=5.9.3 https://pureagrigroup.com/wp-content/uploads/2021/02/logo-7-1.png ONLINE AND OFFLINE UPS/CVCF – Pure Agri Group https://pureagrigroup.com 32 32 ONLINE AND OFFLINE UPS/CVCF https://pureagrigroup.com/product/online-and-offline-ups-cvcf/ Sat, 24 Jun 2023 07:28:25 +0000 https://pureagrigroup.com/?post_type=product&p=697 Range 1 KVA to 20 KVA, Single Phase 5 KVA to 60 KVA, Three Phase Nominal Frequency 47 Hz to 53 Hz DC Voltage (Optional) As per customer's requirement Output (Technology) IGBT Output Voltage 230Volts AC(Single Phase) 400/415 Volts AC (Three Phase) Voltage Regulation +/-1% for DC 1/P variation & O/P load variation 50Hz +/- 0.05 Hz 50Hz +/- 0.05 Hz Any optional frequency Power Factor 0.8 lagging to unity Harmonic Distortion Less than 3% Inverter Efficiency >93% for 360V DC and above >90% for 180V DC Crest Factor 3:1 Overload 125% for 5 Minutes 150% for 60 Sec Audible Noise Less than 45 Db ant 1 Meter Metering LED & Microprocessor based Digital LCD metering for multiple Parameters shall be provided as optional in Higher Capacities
General Operation Temperature 0°C to 50°C
'Humidity Max 95%, Non-condensing
Protection Inverter Trips
(DC Under Voltage) Inverter & Charger Trips
Protection Inverter Trips
(DC Under Voltage) Inverter & Charger Trips
(DC Over Voltage) Inverter Trips
(Output Under Voltage) Inverter Trips
(Output Over Voltage) Inverter Trips
(Output Over Load) (Output Short-circuit) Indication & Alarms Inverter Trips Mains On by Indicator Inverter On by Indicator
(Mains Fall) Indicator & Alarm
(DC Low) Indicator & Alarm
(DC Over Voltage) Indicator & Alarm
(Output Under Voltage) Indicator & Alarm
(Output Over Voltage) Indicator & Alarm
(Output OverLoad) Indicator & Alarm
By Pass Facility (Static Bypass Switch) Manual Bypass Switch (Provided as Standard feature) Bi-directional (Optional)
Isolation of Power (Input) (Output) (Battery) MCB Provided Switch/MCB (Optional) HRC fuse / MCB (Optional)
]]>
 

Range 1 KVA to 20 KVA, Single Phase 5 KVA to 60 KVA, Three Phase
Nominal Frequency 47 Hz to 53 Hz
DC Voltage (Optional) As per customer’s requirement
Output (Technology) IGBT
Output Voltage 230Volts AC(Single Phase) 400/415 Volts AC (Three Phase)
Voltage Regulation +/-1% for DC 1/P variation
& O/P load variation
50Hz +/- 0.05 Hz
50Hz +/- 0.05 Hz
Any optional frequency
Power Factor 0.8 lagging to unity
Harmonic Distortion Less than 3%
Inverter Efficiency >93% for 360V DC and above >90% for 180V DC
Crest Factor 3:1
Overload 125% for 5 Minutes 150% for 60 Sec
Audible Noise Less than 45 Db ant 1 Meter
Metering LED & Microprocessor based Digital LCD metering for multiple Parameters shall be provided as optional in Higher Capacities
General Operation Temperature 0°C to 50°C
‘Humidity Max 95%, Non-condensing
Protection Inverter Trips
(DC Under Voltage) Inverter & Charger Trips
Protection Inverter Trips
(DC Under Voltage) Inverter & Charger Trips
(DC Over Voltage) Inverter Trips
(Output Under Voltage) Inverter Trips
(Output Over Voltage) Inverter Trips
(Output Over Load) (Output Short-circuit) Indication & Alarms Inverter Trips Mains On by Indicator
Inverter On by Indicator
(Mains Fall) Indicator & Alarm
(DC Low) Indicator & Alarm
(DC Over Voltage) Indicator & Alarm
(Output Under Voltage) Indicator & Alarm
(Output Over Voltage) Indicator & Alarm
(Output OverLoad) Indicator & Alarm
By Pass Facility (Static Bypass Switch) Manual Bypass Switch (Provided as Standard feature)
Bi-directional (Optional)
Isolation of Power (Input) (Output) (Battery) MCB Provided
Switch/MCB (Optional)
HRC fuse / MCB (Optional)
]]>